CVE-2024-39518

CVSS v3 Score
7.5
High

Vulnerability Description

A Heap-based Buffer Overflow vulnerability in the telemetry sensor process (sensord) of Juniper Networks Junos OS on MX240, MX480, MX960 platforms using MPC10E causes a steady increase in memory utilization, ultimately leading to a Denial of Service (DoS). When the device is subscribed to a specific subscription on Junos Telemetry Interface, a slow memory leak occurs and eventually all resources are consumed and the device becomes unresponsive. A manual reboot of the Line Card will be required to restore the device to its normal functioning. This issue is only seen when telemetry subscription is active. The Heap memory utilization can be monitored using the following command: > show system processes extensive The following command can be used to monitor the memory utilization of the specific sensor > show system info | match sensord PID NAME MEMORY PEAK MEMORY %CPU THREAD-COUNT CORE-AFFINITY UPTIME 1986 sensord 877.57MB 877.57MB 2 4 0,2-15 7-21:41:32 This issue affects Junos OS: * from 21.2R3-S5 before 21.2R3-S7, * from 21.4R3-S4 before 21.4R3-S6, * from 22.2R3 before 22.2R3-S4, * from 22.3R2 before 22.3R3-S2, * from 22.4R1 before 22.4R3, * from 23.2R1 before 23.2R2.

CVSS:7.5(High)

389-ds-base before version 1.3.6 is vulnerable to an improperly NULL terminated array in the uniqueness_entry_to_config() function in the "attribute uniqueness" plugin of 389 Directory Server. An auth...

CVSS:7.5(High)

389-ds-base before versions 1.4.0.9, 1.3.8.1, 1.3.6.15 did not properly handle long search filters with characters needing escapes, possibly leading to buffer overflows. A remote, unauthenticated atta...

CVSS:7.5(High)

procps-ng before version 3.3.15 is vulnerable to a denial of service in ps via mmap buffer overflow. Inbuilt protection in ps maps a guard page at the end of the overflowed buffer, ensuring that the i...

CVSS:7.5(High)

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing t...

CVSS:7.5(High)

In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could...

CVSS:7.5(High)

An issue has been found in libIEC61850 v1.3. It is a SEGV in ControlObjectClient_setCommandTerminationHandler in client/client_control.c. NOTE: the software maintainer disputes this because it require...